MAGNETO-LASER THERAPY APPARATUS "VECTOR-03"

 


  Red light laser therapy with magnetic field therapy

      Magneto-laser therapy apparatus Vector-03   


  Transportable (180x100x40 mm) magneto-laser therapy apparatus "Vector-03" is a medical-technical embodiment of Ancient East and modern medical achievements with the absolute absence of pain sensations (the puncture is made by laser beam, gently and painlessly influencing on different areas and body parts).

Indications:
for medical-prophylactical procedures by means of blood irradiation (through skin, overvein), influence on lesion body parts by laser irradiation and magnetic field.

Application:
in different modern medicine fields: cardiology, pulmonology, gastroenterology, common and purulent surgery, stomatology, dermatology, angiology, proctology, urology, gynaecology, neurology, otolaringology, traumatology.

  • The device is transistorized multifunctional laser apparatus of new generation, meets modern medicine high requirements: noninvasity, simple control, the precise dosage of influence on organism, small size, universality, possibility of combining with different diagnostical and physiotherapeutical devices.
  • The medical procedure is painless and is easily borne by patient. There are no side effects; atraumatism makes the apparatus irreplaceable in pediatrics.
  • The apparatus application by specialists, worked in a field of practical reflexotherapy, promotes to increase efficiency to a considerable extent and to optimize the treatment quality.
  • Depending on medical purposes, stimulating, inhibiting and harmonizing effects can be reached.
  • It is expedient to form group with one form of pathology.
  • The investigations show, that red radiation with wave length and power provided by apparatus, has a medical effect, influencing on acupuncture points, that is analogous to acupuncture therapy, that is to say, it works under a law of weak irritator, providing normalization of affected physiological and biochemical organism processes, the renewal and reinforcing of homeostasis.
  • The apparatus can be used in hospital and out-patient conditions by doctor, nurse and patient himself after physician recommendation.

  • Apparatus "Vector-03" technical data
    radiation wave length 670 nm;
    performance modes continuous; pulse;
    power supply 4 type AA (R-6) elements;
    the continuous performance time up to discharge 8 h;
    radiation power up to 9 mV;
    radiation pulse frequency 5, 20, 77, 125, 500, 1200 Hz;
    magnetic field tension 35 mTl;
    the single cycle time is continuous or is set by timer 10, 20, 30, 60, 90 s;
    dimensions, not more than 180x100x40 mm;
    weight, not more than 0,3 kg.

     

     